Catalogue / SR-9011
SR-9011
Also written as SR9011.
The pentyl urea analogue of SR-9009, sharing its chlorobenzyl nitrothiophene core and differing by 41 daltons.
| Molecular formula | C23H31ClN4O3S |
| Average mass | 479.04 Da |
| Monoisotopic mass | 478.1805 Da |
| Molecular target | REV-ERB |
| Electrospray polarity | Positive |
| Class | Non-androgenic compounds sold in the same category |
| Determination | Small molecule analysis, reference standard sourced to order |
| Price | 527 USD |
Computed at build time from the composition shown on this page, not transcribed from a supplier datasheet.
SR-9011 has an average molecular weight of 479.04 daltons and a monoisotopic mass of 478.1805 daltons, computed from the molecular formula C23H31ClN4O3S. Identity is confirmed by matching the measured mass against a certified reference standard, and purity is reported separately by reversed-phase chromatography at the compound's own ultraviolet maximum rather than at the 214 nm used for peptides. Neither figure states which enantiomer is present, which is a third determination on a chiral stationary phase.
| Ion | m/z |
|---|---|
| [M+H]+ | 479.1878 |
| [M-H]- | 477.1733 |
Usable response for this compound is in positive mode. The other ion is given because it is the one a wrongly configured method looks for.
A molecule of this size does not produce the multiply charged envelope a peptide does. It produces one singly charged ion, and which polarity that ion appears in is decided by the functional groups rather than by convenience. A nitro or cyano aromatic responds in negative mode; a basic amine responds in positive.
That is why a screen acquired in a single polarity misses part of its own compound list, and why a non-detect from such a screen is not evidence that a substance is absent. The polarity used belongs on the certificate alongside the result.
| It shares its entire chromophore and its entire fragmentation core with SR-9009. Any determination that identifies by ultraviolet spectrum, by retention or by a single fragment ion will not separate the two; the intact mass will. |
| The same nitro reduction applies, 30 daltons light, with the same requirement for light protection from receipt. |
| The least widely stocked reference standard of this group, so the determination is quoted on the basis that a standard is sourced before the sample is booked in. |
Every compound fails in its own way. A generic peptide method applied without regard to these specifics produces a number that looks like a result and is not one.
A PPAR delta agonist pair, two REV-ERB agonists and a growth hormone secretagogue. All are sold as SARMs and none binds the androgen receptor. The distinction is not pedantry: it is the reason a single method tuned for the aryl propanamides under-reports every compound in this group, and the reason a class screen has to be built from the chemistry rather than from the marketing category.
LC-MS identity against a certified reference standard, with source and polarity chosen per compound because this group spans a basic amine, two neutral thioethers and two nitro heterocycles. Purity by HPLC-UV at the compound's absorbance maximum. The nitro compounds are handled under light protection, because their reduction product is a different molecule at a different mass.
Where the delivered milligram figure matters rather than the percentage, assay against a certified reference standard gives content directly, and where no such standard exists quantitative NMR against a certified internal standard gives an absolute purity that needs no standard of the analyte at all.
| LC-MS identity | Measured mass |
| HPLC-UV purity | Area at the UV maximum |
| Enantiomeric purity | Chiral stationary phase |
| Water content | Karl Fischer |
| Elemental impurities | ICP-MS |
| Residual solvents | GC-MS |
What is the molecular weight of SR-9011?
The average molecular weight is 479.04 daltons and the monoisotopic mass is 478.1805 daltons, computed from the molecular formula C23H31ClN4O3S shown on this page. Both figures are calculated rather than transcribed, so they can be checked against the stated composition.
How is SR-9011 tested for purity and identity?
LC-MS identity against a certified reference standard, with source and polarity chosen per compound because this group spans a basic amine, two neutral thioethers and two nitro heterocycles. Purity by HPLC-UV at the compound's absorbance maximum. The nitro compounds are handled under light protection, because their reduction product is a different molecule at a different mass. Purity is an area ratio measured at the compound's own ultraviolet maximum, and it describes the chromatographable fraction only. It says nothing about which enantiomer is present, because mirror images are not separated by an achiral column.
What goes wrong when SR-9011 is analysed?
It shares its entire chromophore and its entire fragmentation core with SR-9009. Any determination that identifies by ultraviolet spectrum, by retention or by a single fragment ion will not separate the two; the intact mass will.
What does SR-9011 analysis cost at ANALYTON?
Small molecule analysis, reference standard sourced to order is priced at 527 US dollars, covering the determinations described on this page. Content, safety and elemental determinations are ordered alongside and are priced separately on the price list.